New testing conducted at France’s oldest PV system have shown that its solar modules can still provide performance values in line with what the manufacturers promised.

  • DavidGarcia@feddit.nl
    link
    fedilink
    English
    arrow-up
    9
    ·
    5 months ago

    Those are way more interesting than this single installation with -0.66%:

    “Another more recent study carried out by the US Department of Energy’s National Renewable Energy Laboratory (NREL) on 1,700 American sites totaling 7.2 GW of power, showed a median degradation of around -0.75%/year. Moveover, another research focused on 4,300 residential installations in operation in Europe and used different data processing methodologies. Depending on the methods, a median loss of -0.36% to -0.67%/year was obtained.”

    Also the article doesn’t mention standard deviation or IQR of the drop, or what efficiency they originally had. Which is the minimum of information I would expect.

    • MigratingApe@lemmy.dbzer0.com
      link
      fedilink
      English
      arrow-up
      4
      ·
      edit-2
      5 months ago

      You are totally right. Median and average alone mean shit without each other and without deviation, and such article like this is considered by me a manipulation without further correctness check. The same shit is with journalists confuckulating percentages with percentage points.

      In over 10 years I was made aware by my university professor of these practices I haven’t found a single article which got that right.