Hey!

Currently doing drywall myself and I am using 6x6 cm squared timber around my outside walls.

The problem is they aren’t as stable as the other walls inside the house because of the 6x6 cm squared timbers that are about 30cm distance from each other.

I will screw my plasterboards on the squared timber and only one plasterboard, not two.

I have two pictures of what my construction looks like from far and one from close.

Maybe someone can give me advice before I install the plasterboard onto it.

The only problem I currently see is finding the subconstruction once I put the plasterboards back on. But other than that, if I find them can I install the cabinets safely?

  • Death_Equity@lemmy.world
    link
    fedilink
    arrow-up
    4
    ·
    9 months ago

    They are not American, Germans build way different so how they do things does not make sense without understanding what is going on.

    • Grogon@lemmy.worldOP
      link
      fedilink
      arrow-up
      1
      ·
      9 months ago

      I think people don’ know that the “studs” what I didn’t know were are hidden behind the Plywood.

      • roguetrick@kbin.social
        link
        fedilink
        arrow-up
        1
        ·
        edit-2
        9 months ago

        Yeah, folks are having a hard time wrapping their head around how it structurally works but it obviously does since they’re building housing developments with it. The picture just shows the sill plate and top plate (the two thick pieces of wood on the top and bottom of the wall behind the OSB[what we call the plywood on the inside]) with insulation sandwiched between, but there has to be lengths of wood going from those to hold them together (which we call studs). They’re mistakenly thinking that your 6x6 cm pieces of wood are those studs.

        • Grogon@lemmy.worldOP
          link
          fedilink
          arrow-up
          3
          ·
          edit-2
          9 months ago

          So I guess I should be fine?

          I am having heart attack and panic right now.

          My construction dude told me to apply 6x6 cm squared timber for installation (electricity) and spread the about 30 cm apart from each other around the house. Once the electrician comes and installs everything and is finished I can install plasterboard onto the 6x6cm squared timber.

          I am just not sure if I can hang anything on the plasterboard that is attached to 6x6cm timber. It would be alot more stable if I could get rid of the 6x6cm timber and attach plasterboard to plywood (like the inside walls).

          At the end he said it’s for electricity only and my safety so I don’t break the vapor barrier later if I screw something into the plasterboard. So I have about 6 cm “air” before the “real” wall starts after the plywood.

          Its basically from inside to outside:

          Plasterboard -> 6x6 cm squared timber -> Plywood -> Studs -> Vapor Barrier -> Insulation (240mm wool) ->… in the end the totall wall is about 39cm thick.

          • roguetrick@kbin.social
            link
            fedilink
            arrow-up
            1
            ·
            edit-2
            9 months ago

            So are the 6x6s attaching just into the plywood or are they going into something behind the plywood? Overall it sounds fine what he told you to do, but what they’re attaching to and how you do what we call “blocking” to secure them is how you determine if you can hang cabinets.

            Edit: Per your additional information, what you’re doing is fine but I’d ask him specifically about where you want to hang cabinets because you’d need to make more consideration. They put a lot more strain than thin drywall to the fasteners that are holding them up.

            • Grogon@lemmy.worldOP
              link
              fedilink
              arrow-up
              2
              ·
              9 months ago

              I have bigger screws in those that go into a bigger piece of wood behind the plywall.

              I guess it’s the studs then. So my 6x6 cm squared timber that I am installing vertically is going into studs behind the plywall

              • roguetrick@kbin.social
                link
                fedilink
                arrow-up
                1
                ·
                9 months ago

                Yeah, that’s essentially fine. You likely can hang cabinets off of them, but I’m not a cabinet installer or a framer. I’m a nurse that used to sell building supplies. You should ask him if you need more reinforcement for your cabinets. For your drywall everything’s fine.

                • Grogon@lemmy.worldOP
                  link
                  fedilink
                  arrow-up
                  2
                  ·
                  9 months ago

                  Alright cool.

                  Yeah well I am just a nurse too (but in germany) or else I’d not have to ask here lol.

                  I sent a picture of the subconstruction to the kitchen company and they will tell me more.

    • Taleya@aussie.zone
      link
      fedilink
      arrow-up
      1
      ·
      9 months ago

      Not just germans, aussie here, assumed that was internal walls (which differ from external). Seen a few double brick/ concrete framed out like that

      Mind you our building standards have gone down the shitter since the 90’s…